toyota 22re 5 speed 1994 fuel injected motor 2x2 just a daily driver and work truck.
All at once the truck did not start cranks over fine. has gas I removed the coil wire and no spark to ground. I did the ohm meter check of the coil and got .7 primary calls for .36 to .55 I am guessing that is in range and got 12.2k for the secondary call for 9-15.4.
checked the signal generator at 220 ohms calls for 185-265 and the air gap in the distributor is about .10 calls for .08-.16.
The only slight discrepancy is the primary ohms.
I do not no where to check for power to the ignition system.?????
I disconnected the tachometer that I added just in case, Then tried it with the tack and did not see the tach move while cranking.
not sure what to test next and do not want to make a mistake on parts replacement any help is appreciated.
This is the only problem I have had other then a couple of weeks I go I change out the whole clucth system for new at 195,000
thanks ED
|